Chapter 3 - Commissioning
BreezeACCESS VL System Manual
86
Table 3-10: SU-I SNR Bar LED Functionality
SNR Bar LEDs SNR (typical)
LED 1 (red) is On Signal is too low (SNR < 4 dB)
LED 2 (green) is On SNR > 4 dB
LEDs 2 to 3 (green) are On SNR > 8 dB
LEDs 2 to 4 (green) are On SNR > 13 dB
LEDs 2 to 5 (green) are On SNR > 19 dB
LEDs 2 to 6 (green) are On SNR > 26 dB
LEDs 2 to 7 (green) are On SNR > 31 dB
LEDs 2 to 8 (green) are On SNR > 38 dB
LEDs 2 to 9 (green) are On SNR > 44 dB
LEDs 2 to 9 (green) and 10 (orange) are On Signal is too high (SNR > 50 dB)
3.5.4 Verifying the Ethernet Connection (Modular
Base station)
After connecting the unit to an Ethernet outlet, verify that the Ethernet Integrity
Indicator, which is the yellow LED embedded in the 10/100 BaseT connector, is
on. This indicates that the unit is connected to an Ethernet segment. The
Ethernet Activity Indicator, which is the green embedded LED, should blink
whenever the unit receives or transmits traffic on the 10/100 BaseT port.
3.5.5 Verifying the Indoor-to-Outdoor Connection
(Modular Base Station)
After connecting the unit to an Ethernet outlet, verify that the Ethernet Integrity
Indicator, which is the yellow LED embedded in the RADIO connector, is on. This
indicates that the unit has detected an Ethernet link connection. The Ethernet
Activity Indicator, which is the green embedded LED, should blink whenever the
unit receives or transmits traffic on the RADIO port.
3.5.6 Verifying Data Connectivity
To verify data connectivity, from the end-user’s PC or from a portable PC
connected to the unit, ping the Access Unit, or try to connect to the Internet.