Alvarion BREEZEACCESS SW VERSION 5.1 Manuel d'utilisateur Page 193

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 273
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 192
Menus and Parameters
Operation and Administration
161
After reset, the Interference Mitigation statistics file will be updated, and
depending on the Scanning Type you defined, the unit may be configured to a
new operating channel and/or noise floor.
4.2.6.2.19.4 Delete Statistics File
Deletes the Interference Mitigation statistics file created during the previous scan.
A final validation is required prior to deletion:
0 – Cancel Operation
1 – Delete File
4.2.6.2.19.5 Show Interference Mitigation Parameters & Data
This feature displays a review of the Interference Mitigation settings and the
statistics generated during the latest scan (if the statistics file was not deleted in
the meanwhile). These statistics include for each defined channel the following
parameters:
Frequency
Noise Floor
Achievable Distance
Maximum Throughput
Vue de la page 192
1 2 ... 188 189 190 191 192 193 194 195 196 197 198 ... 272 273