Alvarion BreezeACCESS 900 Manuel d'instructions Page 160

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 324
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 159
2-30
BreezeACCESS Version 4.5 Operations and Administration
Manual Revision: 1.0
High Retransmissions Rate Alarm
Severity: Minor, Major
On Conditions: Minor Severity Alarm:
a. The Retransmissions Current Rate exceeds the
Retransmissions Minor Alarm Threshold, and is
higher than the Retransmissions Average Rate by at
least Retransmissions Minor Alarm Minimum Delta,
-OR-
b. The Retransmissions Current Rate has dropped below
the Retransmissions Major Alarm Threshold but is still
higher than the Retransmissions Minor Alarm
Threshold.
Major Severity Alarm: The Retransmissions Current Rate is
higher than the Retransmissions Major Alarm Threshold.
Off Conditions: a. The Retransmissions Current Rate has dropped below
the Retransmissions Minor/Major Alarm Threshold,
-OR-
b. All alarms were cleared,
-OR-
c. AU Alarms Option was disabled
Possible Problem: a. Transmitter or receiver fault
b. Poor link conditions, strong interference, or an
overloaded network.