Alvarion BreezeACCESS 900 Manuel d'instructions Page 161

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 324
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 160
Menus and Parameters
2-31
BreezeACCESS Version 4.5 System Manual
High Dropped Frames Rate Alarm
Severity:
Minor, Major
On Conditions: Minor Severity Alarm:
a. The Dropped Frames Current Rate exceeds the Dropped
Frames Minor Alarm Threshold, and is higher than the
Dropped Frames Average Rate by at least Dropped
Frames Minor Alarm Minimum Delta,
-OR-
b. The Dropped Frames Current Rate has dropped below
the Dropped Frames Major Alarm Threshold, but is
still higher than the Dropped Frames Minor Alarm
Threshold.
Major Severity Alarm: The Dropped Frames Current Rate is
higher than the Dropped Frames Major Alarm Threshold.
Off Conditions: a. The Dropped Frames Current Rate has dropped below
the Dropped Frames Minor/Major Alarm Threshold,
-OR-
b. All alarms were cleared
-OR-
c. AU Alarms Option was disabled
Possible Problem: a. Transmitter or receiver fault
b. A severe case of poor link conditions, strong
interference, or an overloaded network.
Vue de la page 160
1 2 ... 156 157 158 159 160 161 162 163 164 165 166 ... 323 324

Commentaires sur ces manuels

Pas de commentaire